MANUA LM310Blackbody Calibration Source
M310 Manual Introduction 102.4 DimensionsM310 Front PanelM310 Back Panel
M310 Manual Installation 113 Installation3.1 LocationSelect a stable location on which to place the M310. Since any blackbody source stability can
M310 Manual Installation 12To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Operation 134 Operation4.1 Starting Up1. Allow the M310 to warm-up to room temperature for at least two hours afterunpacking and prior
M310 Manual Operation 144.4 Changing Temperature Units (C-F, F-C)The controller has been locked out except for setpoint change to hinder tampering
M310 Manual Operation 158. Press UP to select according to chart below.9. Press SCROLL and hold for 3 seconds to exit.Note: It is important to loc
M310 Manual Operation 16To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Communications Port 175 Communications Port5.1 RS232CThis blackbody may have the option to communicate with the temperature controller
M310 Manual Communications Port 18RS485 wiringThe blackbody was shipped with the controller set at the following com port parameters: Baud: 1200
M310 Manual Communications Port 19Controller response:%0101R0902.000N8<CR>Command line to change blackbody setpoint to 30C:$0101W0930.000F5&l
Confidential InformationThe material contained herein consists of information that is the property of LumaSenseTechnologies and intended solely for us
M310 Manual Communications Port 20To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Maintenance 216 Maintenance6.1 Cavity LifeThe life expectancy of the cavity depends on the time and temperature of operation. The highe
M310 Manual Maintenance 22To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Index 23IndexAAir Outlet Clearance 11Apparent Emissivity 9Appropriate use 9BBackground Influence 9Baud Rate 14CCavity life 21Cleaning 2
M310 Manual Index 24To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Appendix A: Sample Communication Program 25Appendix A: Sample CommunicationProgramThis is a typical QBASIC program that reads current t
M310 Manual Appendix A: Sample Communication Program 26 PRINT USING "##.###"; getpval LOCATE 6, 40 PRINT "new setpoint in&q
M310 Manual Appendix B: Calibration Methods 27Appendix B: Calibration MethodsThere are two distinctly different methods of calibration, each with i
M310 Manual Appendix B: Calibration Methods 28Emissivity (for M310, M315, M320, M316 series blackbodies)When measurements are required at wavelengt
M310 Manual Appendix B: Calibration Methods 29When calibrating infrared sensors at wavelengths other than 8-14 µm region, the graph belowdisplays t
M310 Manual Contents iiiContents1 General Information ...
M310 Manual Appendix B: Calibration Methods 30Example 1: The HT (450 C) blackbody was factory calibrated to provide effective emissivity =1.0 at 8
M310 Manual Appendix B: Calibration Methods 31Example 2: The standard (350 C) blackbody was factory calibrated to provide effectiveemissivity = 1.
M310 Manual Appendix B: Calibration Methods 32Example 3: The HT (450 C) blackbody was factory calibrated to provide effective emissivity =1.0 at 8
M310 Manual Appendix B: Calibration Methods 33Using the M310 to calibrate “fixed emissivity” pyrometersFor convenience, the table below shows what
M310 Manual Appendix B: Calibration Methods 34To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Appendix C: CE Certification 35Appendix C: CE Certification
M310 Manual Contents iv6.6 Heater Element Replacement ... 21Index ...
M310 Manual General Information 51 General Information1.1 Information about the user manualCongratulations on choosing the high quality and highly
M310 Manual General Information 61.3 Limit of Liability and WarrantyAll general information and notes for handling, maintaining, and cleaning this
M310 Manual General Information 7 Telephone +33 (0)3 88 98 98 01 Email: [email protected] Shipments to LumaSense for RepairAll RMA sh
M310 Manual General Information 8To ensure consistent document formatting, this page was intentionally left blank.
M310 Manual Introduction 92 Introduction2.1 DescriptionThe M310 is a portable blackbody calibration source utilizing a digital indicating temperatu